Railsystems

Content:
1. Aluminium contact-conductor line rails
2. Load rails



Aluminium contact-conductor line rails
with non halogen plastic insulator


Type: ASS 1 / ASS 2 / ASS 3

Aluminium contact-conductor line rails with integral copper-conductors, available with 2 - 7 poles and a very high loading capacity. With this systemrail you are able to move heavy loads and power supplies. In connection with the systemcomponent traction the equipment can be moved by motor. Individual controlconcepts are available as well as miscellaneous positioningsystems.

Technical data of the rail
Technical data of the collector



ASS 1
ASS 2
Collector
Span (m) 2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5 6,0
Concentrated load (N) 3816,0 2442,2 1696,0 1246,0 954,0 753,7 610,5 504,6 424,0
Line load (N/m) 3052,8 1563,0 904,5 569,6 381,6 268,0 195,3 146,7 113,0
Deflexion (L/200) (mm) 10,0 12,5 15,0 17,5 20,0 22,5 25,0 27,5 30,0
Material: AL MG Si 05 F 22-25. Dead weight: 2,8 kg/m


Span (m) 2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5 6,0
Concentrated load (N) 11592,0 7418,8 5152,0 3785,1 2898,0 2289,7 1854,7 1532,8 1288,0
Line load (N/m) 9273,6 4748,0 2747,7 1730,3 1159,2 814,1 593,5 445,9 343,4
Deflexion (L/200) (mm) 10,0 12,5 15,0 17,5 20,0 22,5 25,0 27,5 30,0
Material: AL MG Si 05 F 22-25. Dead weight: 3,4 kg/m


Span (m) 2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5 6,0
Concentrated load (N) 19162,4 12263,9 8516,6 6257,1 4790,6 3785,1 3065,9 2533,8 2129,1
Line load (N/m) 15329,9 7848,9 4542,2 2860,4 1916,2 1345,8 981,1 737,1 567,7
Deflexion (L/200) (mm) 10,0 12,5 15,0 17,5 20,0 22,5 25,0 27,5 30,0
Material: AL MG Si 05 F 28. Dead weight: 6,66 kg/m





Type: ASS XXL 2


ASS XXL 2
Aluminium contact-conductor line rail with integral copper-coductors, available with 2 - 20 pol. and extreme load capacity. This system should be applied if there are very high loads to move or if there is a high amount of power and data transfer to manage.

Technical data of the rail
Technical data of the collector



Collector

Span (m) 2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5 6,0
Concentrated load (N) 23364,0 14952,9 10384,0 7629,0 5841,0 4615,1 3738,2 3089,4 2596,0
Line load (N/m) 18691,2 9569,9 5538,1 3487,5 2336,4 1640,9 1196,2 898,7 692,2
Deflexion (L/200) (mm) 10,0 12,5 15,0 17,5 20,0 22,5 25,0 27,5 30,0
Material: AL MG Si 05 F 22-25. Dead weight: 16,6 kg/m





Typ: EHB +

Aluminium contact-conductor line rails with integral copper-conductors, available with 2 - 7 poles and a very high loading capacity. With this systemrail you are able to move heavy loads and power supplies. In connection with the systemcomponent traction the equipment can be moved by motor. Individual controlconcepts are available as well as miscellaneous positioningsystems.

Technical data of the rail
Technical data of the collector



Span (m) 2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5 6,0
Concentrated load (N) 33264,0 21288,9 14784,0 10861,7 8316,0 6570,6 5322,2 4398,5 3696,0
Line load (N/m) 26611,2 13624,9 7884,8 4965,3 3326,4 2336,2 1703,1 1279,5 985,6
Deflexion (L/200) (mm) 10,0 12,5 15,0 17,5 20,0 22,5 25,0 27,5 30,0
Material: AL MG Si 05 F 22-25. Dead weight: 8,02 kg/m







Non halogen plastic contact-conductor line rails


Type: HKS 2 - HKS 7


HKS
Non halogen plastic contact-conductor line rails are a practical experienced, sophisticated product. Because of their space-saving construction and their ease of assambly, in the range of moveable powertransfer the application is almost unlimited. By the use of non halogen plastic and touch-protected construction the systemrails offer the maximum possible security. A high fire protection, good insulator properties and the high recycling possibility characterize the rails.

Technical data of the rail
Technical data of the collector



Collector






Technical data
Profil
Material: Noryl, in accordance to DIN: PPO
Colour: light grey
Insulation: group D nach VDE 0110, max. 400V
Leakage path: DIN / IEC 112 /VDE 0303 part 1: CTI 400
Insulation tissue: II
Inflammability: UL 94: 94V - 0; self-extinguishing, non-dripping
Oxigen-Index: ASTM D2863: 31 %
Heat deflection temperature: 90 Grad C
EG-directives: 91/155 EWG, 93/112 EWG, 67/548 EWG, 88/379 EWG
Copper tape 5 mm2 - 25 mm2 / Belastung: 36A - 100A
Material: flat wire, E - Cu58 (CU-ETP)
Material standard: DIN 1787
Stability: > 370
Collector
Material: Polyamid 66, GF - non halogen -
not inflammable
UL Standard 94V - 0
Rollers: PA 6, white
Grinding coal: Bronze / graphite
or
silver / graphite
spring-loaded with about 6N